Characteristics
|
|
Value / Description
|
| Discharge flow rate* |
|
66 lpm | 4 m3 per hour | 280 lbs per day | 140 scfh |
| O2 purity @ discharge flow rate |
|
93% +/- 3% |
| O2 output pressure |
|
5 - 8 psig |
| Operating temperature |
|
0°F to 120°F |
| Operating power |
|
208 VAC, 3-phase, 60 Hz or
380 VAC, 3-phase, 50 Hz |
Power consumption |
|
2.9 kW @ 5 psig output pressure
3.6 kW @ 55 psig output pressure
3.7 kW @ 100 psig output pressure
|
| Amperage (estimate) |
|
11 (22) amps average (max) draw at 208 VAC
7 (14) amps average (max) draw at 380 VAC
|
Base dimensions
Outside enclosure skid dimensions
|
|
50" L x 38" W x 54" H
52" L x 42" W x 56" H |
| Weight of base unit (estimate) |
|
1500 lbs (does not include booster) |
| Average operating cost @ 55 psig** |
|
$0.30 - $0.40 per 100 scf
$0.10 - $0.14 per m3
|
*For applications requiring lower purity of 90%, flow rate increases to 80 lpm
**Measured at USD 0.1 per kWh cost of electricity
Note: Performance parameters stated at standard conditions |